Why to install a warm air hand dryer?
Automatic Hand Dryers
WHAT TO DO IF...
 

… the dryer does not start?

– Check that it is plugged in.
– Check that the master switch has not been triggered..
– In automatic models, check that nothing is blocking the sensor. If so, remove the blockage..
 

… the dryer blows out cold air?

– Replace the heating element.
 

… the machine is very noisy?

– Check the turbine. It should not graze against either the wall or the cover.
– Check that fan wheel screw has not loosened.
 

… loss of power?

– Clean dryer dust as indicated in preventative maintenance.
 

… do you want to remove marks or burns on the cover?

– When soiled, use a normal window-cleaner product or spirit. Do not use abrasive products.
– If the cover is marked with cigarette burns, rub gently with fine water-resistant sandpaper until the marks disappear.
 

… do you want to dismantle the rear plate? (to change the motor or electronic card in automatic models)

The plate is fixed in place by 4 bolt lugs in the base. Press down one-by-one on each bolt lug with a 6-7 socket wrench.
To re-assemble, simply press down with the hands.
 

… the dryer doesn't stop? (for automatic versions)

– On the p.c. board, move the jumper to the position B. See page 6. The dryer is supplied with the jumper in position A, what means maximum sensibility. 
 
NOTE:   When carrying out any form of work on the inner machine parts, first disconnect from power supply.
 

Oct, 08 2007
SANIFLOW LAUCHES the NEW SPEEDFLOW HAND DRYER at the ISSA SHow in Orladno.

Saniflow Corp. ...


Mar, 13 2007
Saniflow Corporation, manufacture of quality warm air hand dryers and bathroom accessories, is ...

Sep, 15 2006
SANIFLOW Corp. , has the honor of making Spain the world’s leading hand-dryer exporter ...
 
 
American Disability Association
American Association of School Administrators
American Institute or Architects
More links
 
 
ISSA/INTERCLEAN
AIA
Latin Builders Association
Greater Miami & the Beaches Hotel Association
 
 
Saniflow Corporation
12800 N.W. 38 Avenue, Miami FL 33054-4525
Tel: 305 424 24 33 Fax: 305 424 24 35 Toll-Free: 1(877)222-9125
Privacy policy | Terms of use
info@saniflowcorp.com
  designed by: neointeractiva.com